Identification des fréquences propres de bâtiments à grande hauteur

Identification of natural frequencies of the spire and pendulum TMD of Samba Tower Riyadh 1 Introduction The purpose of the tests was the characterization of the main dynamic parameters of the spire at the top of the building in order to calibrate the Tuned Mass Damper (TMD) used to mitigate vibrations of the steel structure. The [...]

Identification des principaux modes de vibration de cheminées industrielles

The chimney located in Dunamenti, Hungary, was 102 m high and had a diameter of 5,6 m. It was mounted on a steel framed structure at a height of 35 m and had a 5-ton TMD mounted at the top. Measurements were conducted at the first level platform, at a height of 52 m. [...]

Campagnes de mesures vibratoires et acoustiques dans les habitations suite au trafic routier

L’effet des vibrations sur le confort des personnes en ce qui concerne les vibrations engendrées par le trafic des trams et métros est habituellement évalué sur base des valeurs de référence de la norme DIN 4150-2 dans sa version 1999. L’effet des vibrations sur la stabilité des constructions est évalué sur base de la norme [...]